Size the system before you price it
How many BTU a room needs, what tonnage that becomes, what the furnace has to output, and what size duct carries the air. Eight calculators built on published charts and standard formulas, each one showing its arithmetic and the numbers we chose ourselves.
Calculators
BTU calculator
Cooling and heating load for a room or a whole house, in BTU per hour and kW, with people and kitchen adjustments.
AC tonnage calculator
The nominal tonnage to buy, the exact load behind it, and the airflow the ducts must carry.
Furnace size calculator
Heating load to output BTU, then the gas input at 80, 90 or 96% AFUE, with blower airflow.
Heat pump size calculator
Nominal tonnage, what it delivers at your winter design temperature, and the backup heat gap.
Mini-split size calculator
BTU per room, the head size for each zone, and the outdoor unit at a real connection ratio.
Duct size calculator
CFM to round or rectangular duct at your friction rate, with velocity and the size to install.
Window AC BTU calculator
Room area to capacity using the ENERGY STAR chart, with sun, people and kitchen adjustments.
Insulation R-value calculator
The attic, floor or wall target for your climate zone, the R to add, and the depth it takes.
Featured scenario
A 1,500 sq ft house in climate zone 4
Average insulation, 8 ft ceilings, four people, no kitchen in the cooled space. The same defaults the calculators open with, so you can follow the numbers from page to page:
- 28,200 BTU/h cooling load, or 2.4 tons before rounding
- 2.5 tons the standard air conditioner size that covers it
- 37,500 BTU/h heating load, covered by a 40,000 BTU/h output furnace
Follow it through: BTU calculator → AC tonnage → furnace size → duct size.
Guides
How many BTU per square foot?
The zone-by-zone chart, worked examples, and where the 20 BTU rule breaks down.
AC tonnage chart
Tons to square feet in hot, mixed and cool climates, plus airflow per ton.
Why sizing is the whole game
Almost every HVAC complaint traces back to a size decision: a bedroom that is always cold, a house that feels damp at 72°F, a system that runs for five minutes and shuts off, a far room that never gets air. The equipment may be fine. The size, the ducts or both are wrong. A right-sized system runs longer at lower output, holds a steadier temperature, removes more moisture and lasts longer than an oversized one that was bought “to be safe”.
The industry has an accepted way to get the size right: Manual J, the ANSI-approved residential load calculation from ACCA. It produces a room-by-room report with sensible and latent loads, based on the actual walls, windows, insulation and airtightness of the house. Most states and municipalities require it for new construction and equipment replacement, and a contractor who cannot supply it is using a shortcut.
These calculators are not Manual J. They are the step before it: a way to know whether the number in a quote is in the right range, to choose which size to ask about, and to understand why two contractors gave you two answers. The method page lists every formula and every source so you can check the arithmetic yourself.
How the calculators work
Each tool starts from a published figure and applies adjustments that are visible in the result table. The BTU calculator uses climate-zone BTU per square foot, then the ceiling, insulation and window factors, then 600 BTU/h per person beyond two and 4,000 BTU/h for a kitchen — the last two straight from ENERGY STAR’s room air conditioner guidance. The tonnage calculator divides by 12,000 and rounds up to a half ton. The furnace calculator converts the heating load to output and then to gas input using AFUE. The duct calculator solves the standard friction equation for diameter.
Every result also shows what it cannot know: the duct losses, the orientation, the altitude, the airtightness. That list is not boilerplate. It is the reason the answer is a range check rather than a purchase order.
What the numbers are worth
A square-foot estimate is typically within 20% to 30% of a Manual J for an average house, and further off for an unusual one: a glass-walled addition, a converted attic, a house on stilts, a basement apartment. Treat a result that agrees with the contractor as confirmation, and a result that disagrees by a full ton as a question to ask. Ask for the room-by-room report, the model number, the SEER2 or AFUE rating, and the commissioning measurements. Those four things separate a quote from a price.
Two habits save more money than any calculator. First, fix the envelope before buying capacity: attic insulation to the DOE target, air sealing, and ducts inside the conditioned space. Second, do not replace a working system to gain a size; replace it when it fails or when the load has genuinely changed.
What this site will not do
- No prices. Equipment and labour vary too much by region, and an invented national figure would be misleading. Every page is free of dollar amounts.
- No fake reviews or customer stories. Nothing here was installed in a real house, so nothing here claims to have been.
- No brand recommendations. Capacity tables differ by model, and the right unit depends on the house and the dealer.
- No account. The calculators run in your browser; there is nothing to sign up for.
Where the figures come from
ACCA’s technical manuals for the load, duct and equipment-selection framework; ENERGY STAR for the room air conditioner chart, its adjustments and the heat pump and furnace criteria; the U.S. Department of Energy for insulation R-values, AFUE bands, heat pump behaviour and duct airflow guidance; and the California Energy Commission for duct and airflow requirements. All 12 sources are listed with a URL, a publisher and the date they were read on the method page.
Where a number is ours rather than a published figure — the zone BTU factors, the insulation and window multipliers, the mini-split diversity factor — it is marked house rule and explained. The site is reviewed as a whole on a fixed date, and each page carries the review date.
Popular starting points: BTU calculator · AC tonnage · furnace size · mini-split size · method and sources