AC tonnage chart
How many square feet each air conditioner size covers, in a hot, a mixed and a cool climate — and why the same tonnage covers different areas in each.
Tons to square feet
Cooling capacity is measured in BTU per hour, and one ton is 12,000 BTU/h. The square footage a ton covers depends on the climate, because the same square foot gains more heat in Houston than in Minneapolis. This table uses the climate factors from the BTU calculator, with an 8 ft ceiling and average insulation:
| Nominal size | Capacity | Zone 2: hot | Zone 4: mixed | Zone 6: cold |
|---|---|---|---|---|
| 1.5 ton | 18000 BTU/h | ≈ 820 sq ft | ≈ 1,000 sq ft | ≈ 1,200 sq ft |
| 2 ton | 24000 BTU/h | ≈ 1,090 sq ft | ≈ 1,330 sq ft | ≈ 1,600 sq ft |
| 2.5 ton | 30000 BTU/h | ≈ 1,360 sq ft | ≈ 1,670 sq ft | ≈ 2,000 sq ft |
| 3 ton | 36000 BTU/h | ≈ 1,640 sq ft | ≈ 2,000 sq ft | ≈ 2,400 sq ft |
| 3.5 ton | 42000 BTU/h | ≈ 1,910 sq ft | ≈ 2,330 sq ft | ≈ 2,800 sq ft |
| 4 ton | 48000 BTU/h | ≈ 2,180 sq ft | ≈ 2,670 sq ft | ≈ 3,200 sq ft |
| 4.5 ton | 54000 BTU/h | ≈ 2,450 sq ft | ≈ 3,000 sq ft | ≈ 3,600 sq ft |
| 5 ton | 60000 BTU/h | ≈ 2,730 sq ft | ≈ 3,330 sq ft | ≈ 4,000 sq ft |
Read the columns as “a house this size, of average construction, in this climate”. If your house is tighter than average, the number is conservative; if it has a wall of west glass, it is optimistic. The tonnage calculator applies ceiling and insulation adjustments before it rounds.
Square feet per ton
The inverse is easier to remember. Divide 12,000 by the zone’s cooling factor and you get the square feet one ton covers:
| Zone | Example cities | Cooling factor | Square feet per ton |
|---|---|---|---|
| 1 | Miami FL, Honolulu HI, San Juan PR | 24 BTU/sq ft | ≈ 500 |
| 2 | Orlando FL, Houston TX, Phoenix AZ | 22 BTU/sq ft | ≈ 545 |
| 3 | Atlanta GA, Dallas TX, Los Angeles CA | 20 BTU/sq ft | ≈ 600 |
| 4 | Philadelphia PA, Nashville TN, St. Louis MO | 18 BTU/sq ft | ≈ 667 |
| 5 | Boston MA, Chicago IL, Denver CO | 16 BTU/sq ft | ≈ 750 |
| 6 | Minneapolis MN, Milwaukee WI, Burlington VT | 15 BTU/sq ft | ≈ 800 |
| 7 | Fargo ND, Duluth MN, Caribou ME | 14 BTU/sq ft | ≈ 857 |
| 8 | Fairbanks AK, Utqiaġvik AK | 13 BTU/sq ft | ≈ 923 |
The common “500 square feet per ton” rule is the zone 1 figure. Applying it in Boston oversizes the unit by about 40%, and applying it in Miami is about right. That is the entire problem with national rules of thumb in one example.
What a ton is, and what it is not
A refrigeration ton is 12,000 BTU/h, a definition inherited from the ice trade. It is not the weight of the outdoor unit, the amount of refrigerant, or the electrical draw. A modern 3-ton condenser may weigh 150 to 250 pounds and draw 3 to 4 kW while running. The tonnage printed on the model number is nominal capacity at AHRI conditions, and actual capacity varies with indoor and outdoor temperature.
Because equipment is manufactured in half-ton steps, a calculated load of 3.2 tons becomes a 3.5-ton purchase, and a load of 2.8 tons becomes 3 tons. The half-ton step is why the exact load in the calculator matters: it tells you how much headroom the rounding added.
Airflow and ducts per ton
Each ton needs about 400 CFM of air. That is not a suggestion; it is what makes the coil work and what allows the refrigerant charge to be verified. The duct trunk has to carry the total:
| Size | Airflow | Round metal trunk at 0.1 in. w.c./100 ft |
|---|---|---|
| 1.5 ton | 600 CFM | 12 in |
| 2 ton | 800 CFM | 14 in |
| 2.5 ton | 1,000 CFM | 14 in |
| 3 ton | 1,200 CFM | 16 in |
| 3.5 ton | 1,400 CFM | 16 in |
| 4 ton | 1,600 CFM | 18 in |
| 5 ton | 2,000 CFM | 20 in |
Those trunk sizes come from the duct calculator at the usual 0.1 in. w.c. per 100 ft. A system with a 16 in trunk on a 4-ton unit is a red flag: the equipment may be right and the ducts wrong, which is the most common reason a new air conditioner disappoints.
Where the chart goes wrong
The chart cannot see construction. A 2,000 sq ft house with R-13 walls, single glazing and ducts in a 140°F attic can need a full ton more than the same house with R-21 walls, double glazing and ducts inside the envelope. It cannot see orientation: a west-facing wall of glass adds load in the late afternoon, exactly when the grid is stressed and the house is hottest. It cannot see air leakage, which in an old house can be the largest single term.
It also cannot see the future. A planned addition, a converted garage or a new sunroom changes the load, and the equipment should be sized for the house you will have, not just the one you have now. Tell the contractor about plans before the Manual J.
Reading a contractor’s quote
A quote should name the model, the nominal tonnage, the SEER2 rating, the indoor coil or air handler, the thermostat, the line set, the pad, the permit and the commissioning measurements. It should also say whether the ducts will be sealed or modified. If the tonnage in the quote is more than half a ton above this chart, ask for the Manual J. If it is more than a ton above, get a second quote.
A quote that says only “3-ton system, installed” is not enough information to compare, and it is not enough information to know whether the house will be comfortable next August.
Frequently asked
What tonnage AC for 1,500 square feet?
In zone 2 (hot) 1,500 sq ft is 33,000 BTU/h, or 2.75 tons, which rounds to 3 tons. In zone 4 it is 27,000 BTU/h and 2.5 tons. In zone 6 it is 22,500 BTU/h and 2 tons. The chart below shows every size.
How many square feet does a 3-ton AC cool?
About 1,800 sq ft in zone 2, 2,000 in zone 4, 2,250 in zone 5 and 2,400 in zone 6. The spread is why a single national chart is misleading: the same 3 tons covers 600 sq ft more in Minneapolis than in Houston.
What is the largest residential AC size?
Five tons, or 60,000 BTU/h, is the largest common single residential unit. Above that, equipment becomes commercial, the ducts and electrical service get large, and the usual answer is two systems or a zoned system.
Does a 2-ton unit really cool 1,000 square feet?
Only in a cool climate with good insulation. At 500 sq ft per ton, 2 tons covers 1,000 sq ft. In zone 2 the same 2 tons covers about 1,090 sq ft, but a sunny house with poor insulation may need 2.5 or 3 tons.
How many CFM is each ton?
About 400 CFM per ton: 600 CFM for 1.5 tons, 800 for 2, 1,000 for 2.5, 1,200 for 3, 1,400 for 3.5, 1,600 for 4 and 2,000 for 5. That airflow is what the ductwork must carry.
Should I size on the chart or on Manual J?
Manual J. The chart is a range check and a way to spot a quote that is a full ton off. Manual J is the ANSI standard, it is required by most codes for replacement, and it accounts for the construction that a chart cannot see.
Where these numbers come from
- ACCA Technical Manuals — Manual J, S, D and H — Air Conditioning Contractors of America (ACCA), read Nov 20, 2026
- Room Air Conditioners — sizing chart and adjustments — U.S. EPA ENERGY STAR, read Nov 20, 2026
- California Energy Standards Recognize the Importance of Filter Selection — U.S. Department of Energy, Building America, read Nov 20, 2026 (published Dec 17, 2014)
- 2025 Building Energy Efficiency Standards, Chapter 4 — residential duct and airflow requirements — California Energy Commission, read Nov 20, 2026 (published May 22, 2025)
Numbers that come from our own arithmetic rather than a published table are marked house rule on the method page. No price appears anywhere on this site: no supplier publishes a national one, and an invented number would be worse than no number.
Next: tonnage calculator · BTU per square foot · duct size · method and sources