BTU calculator
How much heat a space gains in summer and loses in winter, in BTU per hour — the number an air conditioner, furnace or heat pump has to match. Cooling and heating are calculated separately because they are separate loads.
The result below is the worked example already filled in. Change a field and press the button to see your own numbers; the result updates in place.
Your answer
28,200 BTU/h cooling
2.4 tons before rounding · 37,500 BTU/h heating · 8.3 kW of cooling
| Cooling load | 28,200 BTU/h | 1,500 sq ft × 18 BTU/sq ft, adjusted for ceiling, insulation and windows |
| Heating load | 37,500 BTU/h | 1,500 sq ft × 25 BTU/sq ft, same adjustments |
| Cooling equipment | 2.5 tons (30,000 BTU/h) | Nearest standard size at or above the load |
| Furnace output | 40,000 BTU/h | Nearest standard output at or above the load |
| Design airflow | 1,000 CFM | 400 CFM per ton at the cooling size |
| People and kitchen | 1,200 + 0 BTU/h | 600 BTU/h per person beyond two, 4,000 BTU/h for a kitchen |
- Zone 4 — mixed: Philadelphia PA, Nashville TN, St. Louis MO.
- Ceiling factor 1.00 × insulation 1.00 × windows 1.00.
- The cooling number is a sensible-load estimate: it covers heat coming through the shell, people and appliances, but not the moisture load separately.
Before you buy
- This is a square-foot screening estimate, not a Manual J load calculation. A Manual J uses your insulation levels, window orientation, duct location and airtightness.
- Oversizing is the common expensive mistake: a unit that is too big cools the air before it removes humidity, so the house feels clammy and the compressor short-cycles.
- If the cooling and heating numbers point at very different equipment sizes, ask the contractor which load they sized to and why.
Sizes either side
- 2 ton — smaller — only if the load is genuinely lower than this estimate
- 3 ton — larger — gives headroom but costs more to run and dehumidifies worse
What a BTU is, and what the answer means
A British thermal unit is the heat needed to raise one pound of water by one degree Fahrenheit. That is a tiny amount, so equipment is rated in BTU per hour: a 24,000 BTU/h air conditioner removes 24,000 BTU every hour it runs at full capacity. The same unit is written BTU/h, BTUH or, loosely, just BTU. When a contractor says “a three-ton unit”, they mean 36,000 BTU/h, because one ton of cooling is defined as 12,000 BTU/h.
The calculator returns two loads. The cooling load is the heat the house gains from sun, warm air, people and appliances on a design summer day. The heating load is the heat it loses on a design winter day. They are not mirror images: a house in Phoenix has a large cooling load and a small heating load, and a house in Minneapolis is the other way round. Buying one machine to cover both only works with a heat pump, and even then the two numbers decide whether you need backup heat.
The formula this calculator uses
The model is deliberately short enough to check by hand:
cooling BTU/h = area × zone cooling factor × ceiling factor × insulation factor × window factor
+ 600 × (people − 2) + 4,000 if there is a kitchen
The heating side uses the same area, ceiling and insulation factors with a heating factor for the zone. The zone factors are the only part that is not arithmetic, and they are the part most likely to be wrong for your house:
| Climate zone | Example cities | Cooling BTU/sq ft | Heating BTU/sq ft |
|---|---|---|---|
| Zone 1 — very hot | Miami FL, Honolulu HI, San Juan PR | 24 | 10 |
| Zone 2 — hot | Orlando FL, Houston TX, Phoenix AZ | 22 | 15 |
| Zone 3 — warm | Atlanta GA, Dallas TX, Los Angeles CA | 20 | 20 |
| Zone 4 — mixed | Philadelphia PA, Nashville TN, St. Louis MO | 18 | 25 |
| Zone 5 — cool | Boston MA, Chicago IL, Denver CO | 16 | 30 |
| Zone 6 — cold | Minneapolis MN, Milwaukee WI, Burlington VT | 15 | 35 |
| Zone 7 — very cold | Fargo ND, Duluth MN, Caribou ME | 14 | 40 |
| Zone 8 — subarctic | Fairbanks AK, Utqiaġvik AK | 13 | 45 |
Those factors are a house rule, not a published table. They are anchored on the 20 to 25 BTU per square foot that ENERGY STAR’s room air conditioner chart works out to for an average room, then moved by climate zone so that Miami lands near 24 and Minneapolis near 15 for cooling. Heating factors run the other way, from 10 BTU per square foot in zone 1 to 45 in zone 8. A real Manual J replaces all of this with wall, roof and window assemblies, which is why the result is labelled an estimate.
Why the same square footage needs a different number in Miami and Minneapolis
The IECC climate zones are built from heating and cooling degree days, so they describe how hard the weather pushes heat through a wall. Zone 1 is very hot and humid, zone 4 is mixed, and zone 8 is subarctic Alaska. The same 1,500 sq ft house has a cooling load near 36,000 BTU/h in zone 1 and near 24,000 BTU/h in zone 5, before any adjustment for construction. Ignoring the zone is the single most common reason a square-foot rule gives a bad answer.
Zone boundaries do not follow state lines, and mountain microclimates can sit two zones away from the nearest city. The DOE insulation page includes the zone map, and a contractor’s Manual J software assigns the zone from the project address. If you are close to a boundary, choose the colder zone for heating and the hotter one for cooling, then let the contractor refine it.
The adjustments that actually move the number
Ceiling height
Cooling and heating move air, not floor. A 10 ft ceiling holds 25% more air than an 8 ft ceiling, so the model multiplies the load by ceiling ÷ 8, capped at 1.6. Cathedral ceilings and open two-storey rooms are the cases where this matters most, and they are also the cases where a square-foot chart is furthest off.
Insulation and air sealing
“Good” means a house built or retrofitted in the last fifteen years, with attic insulation at the DOE target and few draughts. “Poor” means single-glazed windows, an uninsulated attic and a chimney you can feel. The difference between the two settings is 30% of the envelope load, which is often a full ton on a 2,000 sq ft house. Air sealing belongs in the same conversation: a half-inch gap around a flue can leak more heat than an extra R-10 in the attic.
Windows
The window setting scales the load by 5% either way. That is intentionally modest, because window area is already baked into the zone factor and because shading, glazing type and orientation matter more than count. A west-facing wall of single glazing in Texas can add a ton by itself; if that is your house, treat the result as a floor, not a ceiling.
People and kitchens
A seated adult gives off roughly 400 BTU/h of heat; ENERGY STAR’s room-sizing guidance adds 600 BTU/h for each person beyond the first two, which builds in a margin. The calculator follows ENERGY STAR. A kitchen adds 4,000 BTU/h in their chart, which covers a stove, an oven and a refrigerator in an open-plan space. Neither adjustment applies to an empty rental or a storage room.
Cooling BTU and heating BTU are different loads
Cooling has to remove both heat and moisture. The total capacity printed on an air conditioner is split into sensible capacity (temperature) and latent capacity (humidity), and a unit matched only on total BTU can leave a humid house cold and clammy. That is why the airflow target matters: about 400 CFM per ton gives the coil the right face velocity to condense water, while 350 CFM per ton is used in humid climates to wring out more moisture.
Heating has no latent component. The furnace number is an output figure: the heat delivered to the ducts. A 100,000 BTU/h input furnace at 80% AFUE delivers 80,000 BTU/h, and the ducts may lose a further share if they run through an attic. When you compare this calculator’s heating load with a furnace label, compare it with output, not input.
What this calculator cannot tell you
It cannot replace a Manual J. It does not know which way your windows face, how much ductwork runs through the attic, how airtight the shell is, what colour the roof is, or how many appliances run at once. It does not model humidity, altitude, or the difference between a 2×4 wall with R-13 and a 2×6 wall with R-21. It also assumes the space is one open zone; a two-storey house with a closed stairwell behaves like two zones and needs two loads.
What it can do is catch a quote that is wildly wrong. If this page says 2.5 tons and the contractor proposes 5, ask why. If it says 4 and the contractor proposes 2.5, ask for the room-by-room report. A good contractor will show it to you without being offended.
How to use the number when you buy
- Write down both loads, not just the one you are shopping for.
- Ask for the Manual J report and compare its total with this estimate. Within 20% is a normal gap.
- Check the airflow: 400 CFM per ton for cooling, and a duct trunk sized for it. A right-sized unit on undersized ducts still underperforms.
- Prefer the smaller of two sizes when the load sits between them, provided the next size up is not needed for the coldest or hottest design day.
- Spend the difference on insulation and air sealing before spending it on capacity.
Related tools: AC tonnage converts the cooling load to a nominal size, furnace size does the same for heating, and duct size turns the airflow into metal.
Frequently asked
How many BTU do I need for 1,000 square feet?
In a mixed climate (zone 4) with average insulation, 1,000 sq ft works out at about 18,000 BTU/h of cooling and 25,000 BTU/h of heating in this model. In Miami the cooling figure is closer to 24,000 BTU/h; in Minneapolis, cooling falls to about 15,000 BTU/h and heating rises to roughly 35,000 BTU/h.
Is 20 BTU per square foot a good rule?
It is a starting point, not an answer. Twenty BTU per square foot matches ENERGY STAR’s room chart for an average room with an 8 ft ceiling. It is too high for a well-insulated house in a cool climate and too low for a glass-walled room in Phoenix.
Do I add BTU for people?
Yes, for cooling. ENERGY STAR adds 600 BTU/h for each person beyond the first two who regularly occupy the space. Two people are already inside the base figure.
How many BTU is a ton of air conditioning?
One ton of cooling is 12,000 BTU/h. That is a unit definition from the days of ice, not a weight of equipment. A 3-ton air conditioner removes 36,000 BTU/h at its rated conditions.
Should I size for heating or cooling?
Size the cooling equipment to the cooling load and the furnace to the heating load. One machine only does both when it is a heat pump, and then the cooling load usually sets the nominal size with backup heat covering the coldest hours.
Why does my contractor’s number differ from this one?
A contractor’s Manual J uses wall and window areas, insulation R-values, duct location, airtightness and orientation. This calculator uses floor area and a climate factor, so a 20% to 30% difference is normal. Treat this as a range check on the quote.
Where these numbers come from
- ACCA Technical Manuals — Manual J, S, D and H — Air Conditioning Contractors of America (ACCA), read Nov 20, 2026
- Room Air Conditioners — sizing chart and adjustments — U.S. EPA ENERGY STAR, read Nov 20, 2026
- Insulation — recommended R-values by climate zone — U.S. Department of Energy, Energy Saver, read Nov 20, 2026
- Furnaces and Boilers — U.S. Department of Energy, Energy Saver, read Nov 20, 2026
Numbers that come from our own arithmetic rather than a published table are marked house rule on the method page. No price appears anywhere on this site: no supplier publishes a national one, and an invented number would be worse than no number.
Next: AC tonnage calculator · BTU per square foot chart · window AC sizing · how these numbers are built